ProjectMaker 9112 Version History [use Back button to close this window] =============================================================================== March 4, 2009 1: Siemens S7 driver update (V1.02) 2: Computer Interface driver update (1.04) 3: SLC DF1 / MicroLogix driver update (1.05.1) replaces version 1.08. -------------------------------------------------------------------------- Published files: Install_9112_ProjectSelector_V117.exe Install_9112_DataTransfer_V118.exe Install_9112_DataControl_V116.exe Note: It is not necessary to uninstall previous version before installing newer Version ******************************************************************************* ******************************************************************************* August 12, 2008 1: Fix file element 16 access problem in SLC DF1 driver. (Ver 1.08) -------------------------------------------------------------------------- Published files: Install_9112_ProjectSelector_V116.exe Note: It is not necessary to uninstall previous version before installing newer Version ******************************************************************************* ******************************************************************************* June 26, 2008 1: Fix floating point problem in SLC DF1 driver. (Ver 1.07) 2: Fix problem with Auxiliary I\O driver. (Ver 1.01) -------------------------------------------------------------------------- Published files: Install_9112_ProjectSelector_V115.exe Note: It is not necessary to uninstall previous version before installing newer Version ******************************************************************************* ******************************************************************************* February 6, 2008 1: Fix problem in SLC/MicroLogix DF1 driver that did not allow Long type files to be configured as Unsigned Long data type. -------------------------------------------------------------------------- Published files: Install_9112_DataTransfer_V117.exe Install_9112_DataControl_V115.exe Note: It is not necessary to uninstall previous version before installing newer Version ******************************************************************************* ******************************************************************************* January 11, 2008 1: Fix problem in Data Highway + driver. -------------------------------------------------------------------------- Published files: Install_9112_ProjectSelector_V113.exe Note: It is not necessary to uninstall previous version before installing newer Version ******************************************************************************* ******************************************************************************* January 2, 2008 1: Add Computer Interface driver. 2: Add pre-transmit delay option to ModbusRTU driver. 3: Add HTML format help files for Ultra 3000 and ModbusRTU drivers 4: Publish Computer Interface Driver Test Utility -------------------------------------------------------------------------- Published files: Install_9112_ProjectSelector_V112.exe Install_9112_DataTransfer_V116.exe Install_9112_DataControl_V114.exe Install_9112_ComputerUtility_V103.exe Note: It is not necessary to uninstall previous versions before installing newer Versions ******************************************************************************* ******************************************************************************* December 4, 2007 1: Add Siemens S7-200 driver. -------------------------------------------------------------------------- Published files: Install_9112_ProjectSelector_V111.exe Install_9112_DataTransfer_V115.exe Install_9112_DataControl_V113.exe Note: It is not necessary to uninstall previous versions before installing newer Versions ******************************************************************************* ******************************************************************************* May 16, 2006 1: Updates to Port Mapping Project Files. -------------------------------------------------------------------------- Published files: Install_9112_PortMapping_V103.exe ******************************************************************************* ******************************************************************************* April 18, 2006 1: Add SIEI - ARTDriveS Brushless Servodrive driver. -------------------------------------------------------------------------- Published files: Install_9112_ProjectSelector_V110.exe Install_9112_DataTransfer_V114.exe Install_9112_DataControl_V112.exe Note: It is not necessary to uninstall previous versions before installing newer Versions ******************************************************************************* ******************************************************************************* April 4, 2006 1: Add Alpha Gear - Ternary Actuator driver. 2: Add IAI Corporation - Robo Cylinder Actuator driver 3: Add string file support to SLC504 DH+ driver 4: Remove Siemens and Partlow drivers -------------------------------------------------------------------------- Published files: Install_9112_ProjectSelector_V109.exe Install_9112_DataTransfer_V113.exe Install_9112_DataControl_V111.exe Note: It is not necessary to uninstall previous versions before installing newer Versions ******************************************************************************* ******************************************************************************* February 24, 2005 1: Add 38,400 Baud option to SLC500 DF1 driver. 2: Disable Project Upload function from from Data Transfer, Data Control, and Port Mapping applications. -------------------------------------------------------------------------- Published files: Install_9112_ProjectSelector_V107.exe Install_9112_DataTransfer_V109.exe Install_9112_DataControl_V107.exe Install_9112_PortMapping_V102.exe Note: It is not necessary to uninstall previous versions before installing newer Versions ******************************************************************************* ******************************************************************************* April 1, 2004 1: Add 38,400 Baud option to Ultra 3000 driver. 2: Add 115,200 Baud option to Data Highway Plus driver. Requires DH+ module firmware version 1.01. -------------------------------------------------------------------------- Published files: Install_9112_ProjectSelector_V105.exe Install_9112_DataTransfer_V106.exe Install_9112_DataControl_V105.exe Install_9112_PortMapping_V101.exe Note: It is not necessary to uninstall previous versions before installing newer Versions ******************************************************************************* ******************************************************************************* May 30, 2003 1: Add Position Comparator Maximum parameter to Ultra 3000 driver. Comparator function now supports within and outside limits. 2: Add Index Absolute Direction parameter to Ultra 3000 driver. 3: Fix data type for Read Auxiliary Encoder Position parameter in Ultra 3000 driver. -------------------------------------------------------------------------- Published files: Install_9112_ProjectSelector_V1041.exe Install_9112_DataTransfer_V105.exe Install_9112_DataControl_V104.exe Note: It is not necessary to uninstall previous versions before installing newer Versions ******************************************************************************* ******************************************************************************* August 15, 2002 1: Add String File support to SLC500 DF1 & DH485 drivers 2: Allow SystemFault variable to pass File/Element Address indicating where fault exists. (Data Transfer Project only) 3: Delete empty project folders when application is launched. Windows 2000 & XP do not allow the project folder to be deleted while the application is open, only the project files are deleted. 4: Add parameters to Ultra 3000 driver that were previously missing. -------------------------------------------------------------------------- Published files: Install_9112_ProjectSelector_V104.exe Install_9112_DataTransfer_V104.exe Note: It is not necessary to uninstall previous versions before installing Version 1.04 ******************************************************************************* ******************************************************************************* March 13, 2002 1: Add Port Mapping Project Software 2: Added color coding to transfer files within a Data Transfer Project. 3: Added QXL9112 Data Collection Utility Program -------------------------------------------------------------------------- Published files: Install_9112_ProjectSelector_V103.exe Install_9112_DataTransfer_V103.exe Install_9112_DataControl_V103.exe Install_9112_PortMapping_V100.exe Install_QXL9112_V100.exe Note: It is not necessary to uninstall previous versions before installing Version 1.03 ******************************************************************************* ******************************************************************************* February 1, 2002 1: Add the following drivers: - Allen-Bradley PanelView to Ultra 3000 - Allen-Bradley PanelView to Ultra 100/200 - Generic ASCII Serial Printer - Generic ASCII Serial Barcode input 2: Updated the following two drivers to include Long File Type support. - Allen-Bradley SLC DH485 - Allen-Bradley SLC/Micrologix DF1 -------------------------------------------------------------------------- Published files: Install_9112_ProjectSelector_V102.exe Install_9112_DataTransfer_V102.exe Install_9112_DataControl_V102.exe App_Example_PanelView_Ultra_V100.zip Note: It is not necessary to uninstall previous versions before installing Version 1.02 ******************************************************************************* ******************************************************************************* May 15, 2001 1: Add the following three drivers: - Allen-Bradley Ultra 3000 - Allen-Bradley PLC-2 - GE Fanuc, Series 90, SNP 2: Add missing library file in Project Selector -------------------------------------------------------------------------- Published files: Install_9112_ProjectSelector_V101.exe Install_9112_DataTransfer_V101.exe Install_9112_DataControl_V101.exe Note: It is not necessary to uninstall Version 1.00 before installing Version 1.01 ******************************************************************************* ******************************************************************************* April 4, 2001 Initial release on Web. -------------------------------------------------------------------------- Published files: Install_9112_ProjectSelector_V100.exe Install_9112_DataTransfer_V100.exe Install_9112_DataControl_V100.exe ******************************************************************************* ******************************************************************************* .....Use Back Button to close this window.